Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

we calibrate HPLC once in 6 months while iam doing
calibration i came to know that calibration was failed.
then how can i justify that the samples analyzed on the
system during this 6 months was wright? how can i forward in
to the next step for those batches?

Answer Posted / sasikala

Need not to analyze all previous batches but you should
have internal sop which describes how many batches
(immediate previous batches) to be analyzed and how to be
compared. But this anwser not complete one for you.

Is This Answer Correct ?    1 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if rsd failed then what require to do?

823


for which product require to do content uniformity? what is limit of cu?

808


Ph meter can show more than 14 ph reading? Why ph range in between 1 to 14 only?

729


if content uniformity passing but dissolution varrying then what is next step?

866


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

914


which batch require to use for analytical method validation?

793


In rs method development when we are going area normalization method to dilute standard method?

1516


What is a difference between potency and purity?

1208


How to set specification of assay, fisdolution and related substances?

866


WHY given much noise PDA dector then VWD Dector

2084


Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .

903


What is the principle of Thermal conductivity detector and FID?

2722


some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?

2647


if instrument calibration fails then what require to do?

973


what is the extinction coefficient for Indomethacin or at 319nm wave length.

4061