Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how can findout cable fault Location only useing MEGGER

Answer Posted / arun.kalady84

Using megger we can only find out cable is faulty or not .In the case of HV underground cables , for locating the fault we can use fault locating kit or prelocating kit . using fault locating kit we can pin pointing the fault location, Prelocating kit gives exact fault location im meters by calculation(above 50 mA leakage current is required for 132 KV cables)

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.

929


Which cable is use for rtcc control panel

1714


how we arrange the hv side with delta connection in case 33/11kv of transformer.

1946


How cable from Kit-Kat to main switch, from starter to motor are designed?

2050


What are diffrent type of road taxes?

1922


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1866


lorteny method

1943


How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?

2098


how to find the capacitance value of the motor while running??

1854


can any one tell me about the Extra low voltage systems?From where we give supply to these type of systems??

1857


I need bhel electrical test pattern & paper

1790


what are the difference between PLC and embedded

2087


a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5

1649


how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment

1525


What Is Sampling?

1162