Answer Posted / tahir bhatti
as the flux produce by a single phase alternates +ve and -ve. during +ve half cycle of flux, rotor of the motor try to move to one side to couple its megnetic poles to the stator poles (stator poles change at 50c/sec) but the next half cycle it try to move the other side to couple its megnetic poles to the stator poles, due to inertia and fastly change in megnetic pole does not allow the rotor to couple its megnetic poles to the stator alternating pole which results the failure of motor rotation. capacitor produce a split phase which make its own alternating flux 90 degree to the parent flux. thus as the orignal flux comes to its peak +ve value the split flux value become 0 degree.the rotor try to rotate one side and as the orignal flux comes to 180 the split flux by the capacitor comes to 90 and try to couple the megntic fields of rotor and stator.thus the rotor rotates
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
How you calculating the 30 Hp 3 phase AC motor of power what size of cable is used for this motor?
how to control the speed to switched reluctance motor
how to calculate the change over time for star delta starter for different KW motor?
Does magnetomonopoles exists? one maxwell equation strongly suggests no, but how about their existance in plasma?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
. How to calculate the Short Circuit Impedance in Transformer? How to calculate the Short Circuit Impedance in Transformer?
hello! sir i did three year of diploma in electrical (2007- 2010) and now i m a student of electrical engineering. sir can i apply for germany visa for study and part tome work over there?
when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com
12.5 tons a/c is their how much kva generator can recommend to the customer.
why do we have spikes enough to burn electronic boards, when generators are not grounded
Diagram and details of polarity test for Current Transformer 11kv 400/200/100/1A
What aturn on methods of scr?
Why there are some equipment(i.e:TV) that using 2-pin plug instead of three? What happen if there is current leakage? Are we going to get electric shock??
how to changeover ups in this power failur time?
WHAT IS counter flux IN CT?