what is the difference between synchronous generator &
asynchronous generator
Answer Posted / hk
synchronous generator is nothing but an alternator or turbo generator.The synchronous means constant speed achieving the rotor comparing the stator.The synchronous generator is not a self starting generator it directly generates ac emf with out commutator and inside of the machine two type rotor types using ,1)sailent pole type for low speed,2)cylindrical type or non silent pole for high speed
induction motor is a asynchronous generator rotor always try to acheiving the speed of stator but it does nt reach.
in this two types of rotor connection using 1)squrial guage induction type,wound rotors.
| Is This Answer Correct ? | 8 Yes | 1 No |
Post New Answer View All Answers
Operation carried out in thermal power stations?
which fault is severe and why?between lll fault and lllg fault which fault is severe and y?
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
What are the basic component of a cro?
State ohm’s law?
what r the checklist while installing a 380 kva DG set
IN SINGLE PH TRANSFORMER IF LEKAGE IMPEDANCE DROP IS NEGLECTED ,THE FLUX IN THE MAGNETIC CORE and the lekage flux linking a winding are a)proportional to the applied v to the winding i respectively.
how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.
sir pls tell me . our ct specifications are 120/5 ,2 core , 0.2 and 5p10 class , 30va and 30va buden. insted of 30 va i want use 15 va. can i use?
If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
What will happen if a dc source is given to a tubelight. Will it work or wont it work....
L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.
what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator