loss on drying we applied vaccum for some compounds and
some compounds are at 105c why
Answer Posted / virender
In a Vacuum Oven, the thermal processes occur in an airtight
chamber where a desired level of vacuum has been applied
using an external vacuum pump (not included). With a vacuum
oven the entire application can take place under vacuum or a
controlled atmosphere can be created through the
introduction of an inert gas. Vacuum ovens can help in the
prevention of surface reactions (such as oxidation),
decontaminating samples (removing lubricants for example) as
well as for speeding up the out gassing process. When
determining the process you will use for a vacuum oven bear
in mind that you will need to size a pump to meet this
application. This requires defining the appropriate chamber
size, the level of vacuum desired, and how quickly you will
need to reach that desired vacuum level.
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
mahagenco syllabus for the post of chemist
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
What if impurity area in control sample coming more as compared to LOQ level of impurity ?
inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?
why multimedia dissolution require to do?
identification is for unknown? qualification for known? reporting for LOQ?
how require to interprit the method precision data of hptlc?
In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?
why octanol used to determine the partition coefficient ?
How would you decide dissolution medium for NCE compound of class I drug
can i use hplc detector to uplc and why?
Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?
How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?
What is the main difference between ODS1 and ODS2 Hplc column.
if you get peak in blank then what require to do?