Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we should use delta connection in primary and star
connection in an distribution transformer, which converts
400v a.c. voltage to 33kv.

Answer Posted / ravishankar.m

Generally we recevied power supply from HT.In HT side there
will be not available neutral source so in primery side we
given delta connection.But in secondary side we must need
nuetral for three phase & single phase equipments so we
will create from oueself (create from earthings) so here
the connection must be a star connection.

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2049


What is current & voltage ? Voltage perform at any load without current or not?

1824


What is the vector group of a transformer,how can it be found out?

1996


what will be the effect if you were using different brands of outlets?

1867


What should be the percentage increase in length of the dead end clamp for bus bar conductor (Hawthorn) after hydraulic pressing and what should be the applied pressure?

1885


How many types of electric motors are there?

1106


what happen if the load connected to the induction motor is taken away? the same question for synchoronous generator in synch i think that the the exitation voltage will appear on the terminal only if so plz answer me

1943


What is Auto Mains Failure Panel & Auto Synchronizing Panel

1878


which connection is safer series or parallel?usually which connection we prefer at home?

9791


Why 3 phase induction motor getting supply in body if one of it's phase is cut

1664


# 4 hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible my email id is sumit_lig189@yahoo.co.in

1954


Does the motor power displayed on the Motor name plate is the mechnical power motor delivers or it is consumed power from the system?

4274


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

740


How eddy current generation support the idea of train braking?

1921


What type of core material is used for metering C.T and protection C.T???

2007