Answer Posted / munesh natrrajan
When the Length of Bars available in the market is many
times smaller than the length required or when pieces of
bars are to be utilized,the bars are required to be lapped
that lapped length is called lap length.
Lap length will be as follows;
Tension - Ld or 30 x diameter of bar,whichever is greater.
Compression - Ld or 24 x diameter of bar,whichever is
greater.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
How to calculate quantity of plum masonry in 1:3:7
how many spacers we need for 1 ton reinforcement? aprox.
Mention what are the composition of a landfill?
What expenses counted in contingencies and how much it is in related to built-up area of the building.
what will happen if one could not properly follow the spacing of slab reinforcement bar?
what are the proper pipes for salt water line
Currently my house construction is going on but we just realized that the portico earth beam couldn't connect with the original earth because the beam rod not extended so Please advice
how to stop beam concrete between column
for a column of size 400*230mm column reinforcement= 8-20x(cant write the symbol,i hope u guys undersstand,something like (fi) column stirups=8x@(4l) 230c/c 1)what does these mean 2)how to calculate quantity of steel for this column(ceiling height 11 ft)
is it fair to recruit another prestressing agency once earlier agency has provided guide cone for post stressing the Concrete -I girders? It is observed that the bearing plate of another agency is not matching with the earlier one resulting in protruded strands after stressing from the face of girder. Kindly advice.
what is smart building materials?
what is thumb rule for calculating the size of ISMB required for a particular length of span
How much material is required for constructing a 2 Lane 2Km rigid pavement road
How to cal. The weight of hollow pipe?
Is there the dry coefficient of cement is constant?