1. what is usage for power factor in industries??
2.why we need to monitor power factor??
Answer Posted / shariff
Power factor is very important for the industries,as they
are main source of inductive loads and it is a burden on
the power transformers(less kVA utilzation),so the power
factor to be maintained above 0.8 pf and also the same to
be monitred to avoid the penalties from the distribution
companies.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
at what basis/standard we have to arrive the current density of aluminium/ copper in busbar?
As we use capacitor bank in 3ph ckt to improve PF, can we use capacitor in single ph domestric use, in house we have Fan,Mixer,electric cooker,iron,tube choke they also lag the system,because it is inductive load. if it is possible to improve PF of single ph system-- if yes- type of capacitor to be used,connection diagram, working in detail. if no-- list it.
What is the most accurate way of testing ELCB?ELCB is better than RCD?
You are of electrical field and you are going for software? Why
why impedance relay is used for medium transmission line protection
why star point of HT motor not earthed?
what is the significance of terminal voltage and phase sequence in the operation of paralleling of two generators?
how will calculate the safe starting current of 3-phase squirrel cage induction motor?
1. What is the exact formula for one weber? for example,(one ampere = one coulomb electron of electrons crossing a point of conductor at one second. i.e, 1A=1Q/1sec)
How to convert 2 phase to 3 phase electricpower in induction moter?
give me atleast four differences between circuit and network
Is there any guideline say about display of earthing value near to earth pit
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
advantage of motor design on higher power factor . normally motors are designed for .8 power factor. what is advantage of designing at .88 power factor
What is inductance?