Answer Posted / surender kumar
It is found in above 11 KV voltage transmission &
distribution line
[1] due to raise in voltage.
[2]Reduction in gap between the line conductors.
[3]air insulation level reduction due to natural weather.
In apearance it is faint circular glow having violet in
colour producing hissing noise.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
xpression 'document.FrmQF.myemail' [
1. transformer design formula ? 2. how to calculate the primary turns and secondry turns ? 3. core types ? 4. how to find the primary current and secondry current ? 5. how to calculate the stacking factor ? 6. range of fulx density ?
What is Percentage impedence of a transformer? why it is expressed at a percentage? what is the importance of percentage impedence in case of a transformer?
For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?
In parallel operation time both NGR’s close or not close if both close what will happen
describe the fully control circuit diagram of ac drives
what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
How do you calculate the actual power consumption of an inductive load appliance. Say, a deep freezer of 200watts
what is meant by skew width in machines?
How to calculate total harmonic distortion level(THD) in VFD? and how can we reduce harmonics?
How the PF control while running DG set with load
What is the role of power pack in substation protection system?
How to design the NGR Resistance
any one please tell taht what type questions will be asked in BHEL interview, i am having interview on 24th Dec, please send this to mail pradeepsistam@yahoo.co.in