In thermocouple could we use the lug for termination or
not,Thermocouple is any time,I am currently concerned with
K type.please let me know if anybody know
Answer Posted / george mathews
The basic principle behind any Thermocouple is that there
are two disimilar material connected at one end that is
called the Hot Junction , and we take our out put from the
other open junction that is the cold junction. But when we
connect a lug there is anather metal thats mean 3 metal and
we ll definitely get a wrong out put and in a high
temperature area or zone this may make a big difference.
| Is This Answer Correct ? | 14 Yes | 5 No |
Post New Answer View All Answers
how to design orifice plate?what is the equation?
Draw symbols of the following :
Explain the key components of control loop?
what is the criteria to decide conductor size of a cable ?
What are the key features of a Distributed Control System? describing the various layers (sensor through to business system interfaces) as well as the hardware, software and security aspects of the DCS.
why we use impulse line of flow transmitter at 45 deg. angle both side of orifice plate.
what is zero and span ?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?
which type of zones used for boiler? & why ?
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.
send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com
What is furnace draft control?
can you provide me full detail about instrumentation in ONGC??