Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we do pcc.?

Answer Posted / kdg

Plain Cement Concrete (PCC) is nothing but a layer between
reinforcement and soil/mud to protect reinforcement as well
as RCC from direct contact of soil/mud beneath the
foundation.

Is This Answer Correct ?    16 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how many tonnes equals to one cubic feet?

1622


a butt weld is specified by

2995


What are the advantages and disadvantages of using plastic and timber fenders?

1096


For what purpose bedding is used under storm water drains?

1057


1.what is the mix proportion for cement soil compressed earth blocks? 2.how to calculate the mix proportion for cement stablised earth soil blocks?

2217


plz.show development and anchorage length in simple diagram.

2507


What is difference between code and standard and specification?

2310


which red: used in roof teping, then use only cement

1969


1.Fe500 and Fe550 having more yield strength than Fe415.But why are we prefering Fe415.? 2. d^2/162 formula for knowing the steel wt/m apply all these three? Thanks.

3240


give me the rate analysis for Bituminous Macadam and SDBC

7356


How to calculate the area in squarefeets ?How much area of sqft for this measurements?East 53.3ft West 54ft North 47.7ft South 51.1ft ?

1894


How to calculate brick work quantity?? Block work quantity??

2469


What is the method of soil replacement test?

2051


load combinations how many types for staad design purpose?

2108


Design a shear wall of length 4.20 m and thickness of 250mm subjected to the following forces.Assume Fck = 25Mpa and Fy = 415Mpa and the wall is a high wall with central part 3440mm x 250mm and two 380mm x 760mm strong bands at each end with following loading. S.No.       Loading        Axial force      Moment     Shear 1               DL+LL          1950              600            20 2           Seismic load       250              4800          700

1944