Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to design the earth grid for lightning protection in an
industry

Answer Posted / prakash soni

1)Several lightining arrester is used at the top of towers
lightning mast ,& buildings.
2)shild or ground wires are used above transmission line.
Gound wires are also used above & throughout the sub
station .
3)40mm or 32mm Ms rod are placed to entire area of plant
with wealding joints.
All lighting arresters and ground wires are connected
through the MS gried.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is value of earth resistance required for substation and equipment earthing and what are the reference guidelines

1808


WHERE NEUTRAL WIRE IS CONNECTED AT DOMESTIC TO TRANSMISSION LINE(SINGLE PHASE TO THREE PHASE)

1841


how we calculate electrical load on a building according to area?

2805


how to flameproof electrical motor on the shaft?

2078


How to know Resistance and Reactance value of main and aux winding of single phase capacitor start capacitor run induction motor to find capacitor value?

2049


WHAT IS VCB SAFETY

1257


Define branch?

1097


dg started in plc mode and load taken later one battery terminal connection will be disconnected by loose connection what will happen for dg and shall we connect battery terminals while dg in load time?

2079


how to calculate IR value of 33KV cable ??

1910


What is the reason for using a GE G101 MCB in place of an EP102 MCB if both are capable of AC circuit protection?

2659


why T/F winding temp measurement cts are odd secondary current ie,109A/1.2A/1.4A?

1871


H.t motor 6600 volt to same motor lt supply 440volt supply applyed to h.t motor to effect....

1900


stand by earth fault protection (51G) for transformer rating 2000 kVA,Dyn11,33/0.400 V. LV NCT ratio and necessary resistor and metrosil values how to calculate

2811


What is the working principle of servo motor? And explain it.

1944


volts=230 c=10mf a=??

2045