why power generated only 11KV not more than????????
and why power up/down is multification of 11*?=??.???
foe Example 11/33,11/66,66/11KV etc,
Answer Posted / thingujam
1) 11kv is a reliable and conventional generating voltage.
2) Multiple of 11KV is a conventional multiplying factor
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
In both 600/1000 V cable and 450/750 V cable, we can supply 415 V. However for distribution, all utilities are using only 600/100 V instead of 450/750 V. What is the reason?
I would like to know that the fault curretn at base load and at 10% generation will be same? Fault level of BUS remain same with different generation?
At what factor resistance r of a conductor depends?
why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?
UG cable sizes were specified in sqmm. But practically its not coming to mesure. What's the reason for that? And how they specify the size of the cable?
which is the best institute for PLC,SCADA,DCS in hyderabad
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
lamination figures
How to choose the vector group for the step up and step down transformers??? Tell me the which vector group is suitable for step up and step down transformers and whats the reason to choose and whats the benefits???
How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?
How to distinguish whether MCB is DC or AC looking at it physically
at what rate the micro controller increment its timer....is it 1micro seconds or 1/(12*10^6) seconds
Either It Possible a dc Motor to Run On Ac Drive [ Ex : ACS 800 , Yaskawa F7 ] If it is Possible How Pls Inform Me dinesh_elect_eng@yahoo.com
distribution transformer de-rating formula on over limit iron losses
i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test