how to distinguish between ac motor and dc motor without
seeing name plate of it.only seeing its getup look
Answer Posted / gurdeep
DC motors have bolts fitted on the outer surface...whereas in case of AC motors the outer surface doesnt contains these bolts.AC motors are conpact in structure and smaller in size as compared to that of dc motors.
| Is This Answer Correct ? | 4 Yes | 5 No |
Post New Answer View All Answers
at what base you will tell the direction of rotation of dc motors and generators?
what is meaning of 230volts ac 50hzs ac supply is it rms or maximum to getting ac 230v what amount of max voltage they will send
How to select the gauge of wire for winding of motors? How to select number of turns for winding of three phase induction motor?
what is PWM in IGBT and how it works for drive.?
Please define ohm’s law for a.c (alternating current)?
what is basic difference betmeen normal & flame proof motor??
what is arc flash and what are the hazards involved
How to detect voltage vector shifting in interconnection protection.
What are the components connected in between the power supply coming from an electric pole to HT & LT Panels in a large commercial building or how the power supply connected from Electric pole to Transformer & then to the HT & LT panels of a building? Please send me answers via mail, my id is yogiagarwal@gmail.com. If possible, please give a line diagram.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
In electrical locomotive engines, the DC series motors is being used as traction motor. But in new engines like in WAP7 & WAG9 the 3-phase squiral cage induction motors has replaced them. So can someone tell me the advantages of induction motor over dc seris motor in engines points of view....???
how to produsing geretor power
sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance
What is the unit of charge and current?