What is the difference between grounding & earthing?
Answer Posted / vinod kumar
grounding and earthing are almost similar terms the
difference is as followes
Grounding:if the current carrying part of the system is
earthed it is called grounding i.e it is done for the
protectoion of power sytstem equipment for example grounding
of neutral point of a star connected transformer.
Earthing:If the non current carrying part of the system is
earthed it is called as earthing i.e it is done for the home
appliances such as computer refrigerator etc...
| Is This Answer Correct ? | 8 Yes | 3 No |
Post New Answer View All Answers
what is the difference between general inverter and solor inverter clerly explain plz
What is the difference between the impedance percent and impedance voltage ?
if voltage bt phase & nutral is 38v in a panel board . whats the root cause.
75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?
Electrical 'C' license full abbreviation , and full form
10 Mtr Hight of Lighting Arrestar how much area coverd??
For group 1 , 2 whather i have to prepare my technical or general studies etc? and im graduate in ee engg. for wht posts im eligible for? please tell me!
before transformer oil dielectric strenght tests are taken the oil should be allowed to settle to remove option 1 air bubbles 2 gasses 3 contamination 4 water
If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines
If we impress a dc voltage of 230 V on an unloaded 230 V, 50 Hz transformer it wi A give high secondary voltage B burn out C give secondary voltage as per K D none of these
use of PIR in ehv breaker
WHAT IS THE TECHNICAL SPECIFICATION OF C CURVE & D CURVE LEGRAND MAKE MCB
What is quadrantal symmetry?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
i have completed deee and i've (June2012-feb 2015 experience in electrical maintenance in pvt ltd company.company having HT & LT electrical power.how to apply electrical C-license ,NOW I was resigned my job,what are requirements of applying for c-license