How to calculate the motor winding resistance ?
Answer Posted / sarath nair
Disconnect motor terminals and check the winding resistance
with a multimeter at the two ends of each coil(U-U1,V-V1,W-
W1) and find the minimum acceptable value by using the
formula (Rated voltage (V)/1000+1)
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
what is RFID? thire application;
What is cross over distortion? How it can be eliminated?
what is parellel power factor correction?
Incoming line 11kv And transformer capacity is 2500kva. Consumption load is 1300A. Then fuse capacity is 11kv line.
In 90 kva alternator that produce the output voltage is 115(p-n),200(p-p) at 1500 rpms means what ampere it produced ?
i am going to attaned the engineer (disign)iterview at HAL please give me duid line
Write the force balance equation of m ideal mass element.
what is earth-fault?when it occurs? to check where it occurs what type of test should we do?
If I have 3 essential main switch board and 3 incoming electricity ,but only 1 genset running is that possible.
how to copy from plc ge fanuc versamax series,all input and output, adress, and printout.
How many sprinklers should be in one pipe line?
why the earth is taken minimum in supplying? wather it the proportional factor to getting work any equipment or a power plant?
How is the gain affected by the introduction of feedback in a control system.
How Can you do Maintenance of ACB of 2000Amperes
How to select the proper VSD to operate high inertial load