Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS DIFFERENCE BETWEEN RRT AND RRF IN HPLC

Answer Posted / naresh t

Relative retention time (RRT) is used to know where peaks apart from main compound elutes in HPLC analysis.

Where as Relative Response factor (RRF) comes into picture when our compound and impurities have different wavelength maxima. In this case impurities show either higher or lower response when the analysis is performed at wavelength maxima of main peak. So in quantification analysis the values obtained for impurities are not the actual values. In order to calculate the actual value of impurities' a correction factor is applies. this factor is called RRF

Is This Answer Correct ?    84 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what type of question will ask in the interview of lab chemist.

3323


Why we check moisture,ash & AIA in product

1885


Qc interview questions

1745


What is stray light in uv what are units for stray light

1654


Why Ethanol is Used for Standardization of GC Head space?

4231


some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?

2656


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

1601


Why a1% value is used for some product ? What is the criteria for selection a1% value ?

2346


why we use glass fiber filters use in some situation?

802


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1973


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

776


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2731


Which parameters require to do in tech transfer?

759


why require to do water content for drug product?

835


cefoperozone and sulbactam inj. hplc test method

2693