IN CABLE TRENCH WHY FILL UP THE SAND. AND WHAT IS THE
DIFFERENCE BETWEEN OVER HEAD AND UNDER GROUND LAYING THE
CABLES
Answer Posted / k.prakashchandra
Sand remains in the form of loose grains forever,hence
location and removal of cable become easy.Overhead cables
require supporting structures and wires.
| Is This Answer Correct ? | 1 Yes | 6 No |
Post New Answer View All Answers
what happen ehen synchronisation is done at below rated speed
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
what are the difference between PLC and embedded
What is difference between insulating medium and fault current interruption medium in a switching device.
Why IR value of the (HT cable Plus synchronous motor) is less while individually having IR values in GΩ?
The 3 phase 400 hp 440 volt slip ring induction motor do not take one phase amps why ? The motor is running good condition
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
explain the process of commutation in a dc machine. Explain what are inter-poles and why they are required in a dc machine.
what is relation between ct and pt ratio with multiplication factor of a energy meter? is there any other factor on which multification factor depend?
state the working of discharge lamp?
Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?
we are having 110 Kv,250mA Electrostatic precipitators for coal fired boilers. what will be static voltage and current after discharge and what time it will remain before earthing?
what is mean by drives?
Can you used moeller lzm1 mccb in a dc system with 125vdc and 20ka short circuit current , beside is it have 24 or 48 volt shunt ? Beside how long current can through from An MCB shunt contacts? (like Z7-AS 24 V)?
How can we increase fuel-power ratio of any DG set?