Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE SPECIFICATIONS CONSIDERED DURING DESIGN FOR THE
OVER CURRENT RELAY?

Answer Posted / appurao. s

For the Over Current Relay, (Mostly CT operated)it will be considered the Ct secondary current either 1A or 5A depends on the system design. Mostly today's digital relays are having the option to select between the range.

Also the time for interrupting the flow of current when the over current phenomena arises. Time setting will be range bound, so that the user can decide.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

2285


Can any body tell me about INNER SHUNT COMPOUND MOTOR diagram?

2120


explain safety measures in alternator?

1785


How PSV sizing being done

2330


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2156


What are the factors influence the choice of an electrc drive?

2080


anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?

1865


In a voltage-controlled current source A A current booster is never used B The load is always floated C A stiff current source drives the load D The load current equals Isc

1891


please send previous exams question papers

1829


What is The Resistance Formula

1278


what is LSR?

2196


How to know about the rating(voltage and other) of induction motor if its name plate is missing at the manufacturing site.

3380


What should be the percentage increase in length of the dead end clamp for bus bar conductor (Hawthorn) after hydraulic pressing and what should be the applied pressure?

1938


how to control the speed to switched reluctance motor

1948


What is Phase to Phase clearance for 800V System Operating Voltage as per IEC61439

1043