WHAT IS AN INTERLOCK SYSTEM ?? HOW THEY WORKs ?? WHERE IT IS
USED ??? MAINLY ??
Answer Posted / rt langley
Interlock could be to protect equipment or personal. Boiler
loose water flow interlock shuts down boiler to prevent
damage. Flame eye in boiler loose signal interlock shuts off
gas to prevent explosion. Photo eye beam is broken garage
door returns to open position to keep from crushing you.
| Is This Answer Correct ? | 9 Yes | 0 No |
Post New Answer View All Answers
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
What are advantages and disadvantage of the ac supply load cell?
what does the ratio 800-400-300-200/1-1-1-1-1 in the specification of current transformer indicates?
What is zone,loop/fire alarm system?
where proximity sensor installed on tank in loading arm application
what is the input to be given in digital flow meter during the the calibration time?
What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?
What is loop1 and loop2 in MTS LT?
we are having yokogawa centum cs3000 dcs in our power plant. i need some of the operator guides NOT to appear in HIS0163 AND HIS 0162 but it shoul appear in HIS0164 HOW TO DO IT?
Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection
what are the diff. in servo and regulatory control?
What is critcal speed. what is resonant frequency. why we want to cross crtcal speed on higher RPM (early).
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?
Why even multiple power supplu r used in instrumentation system?
WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN