what is the difference between electrical & electronics
Answer Posted / r.nandhini varma
Electrical - Flow of electrons.
Electronics - Controlling the flow of electrons.
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
What is Auto Mains Failure Panel & Auto Synchronizing Panel
Define peak time.
difference between servo motor and synchronous motor
how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
WHAT IS THE MEANING OG (li = 7 In)
in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformer
Explain the purpose of inductor in an electric circuit?
how much excitation voltage required to generate 1mw power?
Can 4pole (3 phase+neautral )RCCB proper functioning in only 3 phase load (no neautral, no Earth) ?
15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help
what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?
how can calculation ate Amps for cabel. Ex-for 1sqmm wire hou many amps we can draw
what is spadar bar .why I use in DC generator.
I am going to appear for the RRB Chennai Section Engineer online exam. Please send me the question papers from 2001 to date to my mail id:upendrakrishna20@gmail.com,plz send me ,or send any other rrb papers plzzzzzzzzzzzzzzzzzz