what is the functional requirement of cement plaster in RCC
members & masonry??
Is it Manditory to do plastering on all RCC members(beams,
Columns, Slabs)?
in what places plasterring could be kept as an optional
one???
Answer Posted / mohammed mohiddin
1.
a> To prtect the structural or any masonary members from
weathering agent.
b> To impart aesthetic look by giving sophisticated
finish.
2.
It is advisible as an additional protection cover for
the RCC cover especially in the region where the members
are exposed to saline weather in coastal area.
3.
a> Where the good finishing is not required
b> Where the economical building required as mentioned
above
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
how do we calculate quantity of cement sand and aggregates in 1m3 of m20 m25 grade concrete?
Which code is used for tor & tmt steel bar?
Special thing in designing a overhead reservoir ? which is different from an ordinary design
within an emergency scenario what are the safe systems of work a coss can setup as part of is duties
Define What is made from large rocks, which protects the base of cliffs?
what does the grad of cement shows (denotes)?
how to determine H- zone in a column? where it will occur?
What is the difference between Rock And Murrum. How to claim that excavated material is not a murrum but rock.
do we decide reinforcement steel , based on bending moment ? give example with continous slab?
how will remove spiderweb cracking in plaster ? what the reasone of make it ?
Define What is unit weight of normal concrete?
In foundation design, while we do the base pressure check, we normally check if the attained pressure value is less than the GROSS BEARING CAPACITY of the soil which is the sum of net bearing capacity of soil and the overburden pressure. Actually, the overburden pressure acts against the net bearing capacity of the soil and I feel that we are actually increasing the bearing capacity value and doing the check. I feel that this is NOT right. Please clarify on this.
As per Kandal suggestions, we have implemented rolling starts on 140 (+/- 5) degrees and we kept 3 rollars to complete the rolling before falling 125 degrees and the Aggregate AIV is below 22. But When the DBM bed is being rolled 3rd high viabration, (Before 1 plain & low ,2 high Viabrations), the aggregate is getting sharp edge agg. projections are damaged. As the literature is said that, the VG-30 Grade having better control the temp. susceptibility than Penetration grade. if so we could not get this problem at site. But we are facing on site. let me know.
what is flashing?
how to calculate the size of triangular ring in rcc column?