What is an analog input - output , digital input - output .
Any example ???? How they r known its ai-ao or di - do
Answer Posted / mahmoud zaki
EX. DI like sensor.limit switch and bush bottom
DO like to run for example motor
for contactor or relay or solnid valve
AI like level transmitter or pressuer transmitter TC
AO like control valve
| Is This Answer Correct ? | 22 Yes | 0 No |
Post New Answer View All Answers
what is droop in governer ,type of droop ,how it work
Give Detail information about plc,dcs,and scada system?
who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
Why are the uses 24vdc in industries
any body please send me the old question papers of ongc test.
how to calibrate Necleuonic level transmitter.?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.
on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon
Please tell me details about Sox,Nox,SWAS analyser????
How to Calibrate Interface Level Troll in field
State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.
what is the field bus calble ? what are diffrences in orang colur cable and black coular calble ?