why capacitor bank always connected in delta,why not in
star to a system?
Answer Posted / abhishek
capacitor is 1/wc. so if we parallaly add it is in series
and if we seriely add it is in parallel.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.
If the Brush of DC motor is shifted by 90 deg, then what happens to voltage and torque? Both voltage and torque are zero. how to justify the answer?
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.
If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?
how to decide no of electrodes for 1600A LT Main incomer panel
can we use trip light with bus coupler?
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
How to design the NGR Resistance
Meaning of ingrace protection for motor.for ex IPXY
what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.
How work of capacitor in dc supply...???
What is meant by earthhing of a magnetic flow meter and when to use empty pipe detection?