Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

60 watts bulb and resistor home heater is connected in
series and 230v is given to the circuit. The heater is
giving some amount of heat. If instant of 60 watts bulb
replace 100 watts bulb what will be the output of the heater?

Answer Posted / anil

output of heater will be greater than that of output of bulb

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.

2201


what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?

2918


What are the factor to be consider for CT selection in 132kV substation?

2077


What is the cut-off rate?

1171


How to know the Max. current caring capacity of the cable by its size ?

1659


WHAT IS LOAD CELL

2160


Explain about 3 phase motor fault current calculation with examples?

2953


Which capacitor is preferred for high voltage and frequency?

1087


what is the difference between neutral and earth

2115


Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not

1646


What is the minimum IR value of HT/ LT cable? Pls post separetely!!!!!

2452


In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..

1950


what is the use of the circle diagram

5626


all interview questions with answers of ntpc (2000-2009

2218


in india per day how much power is generated including all power station

1965