Why we transmit the power at the voltage in the multiple of
11 or 1.1 like 11kv, 22kv, 66kv, 132kv...... some one told
me that it is due to fomr factor 1.1 of sine wave. its fine
but while transforming we can choose any voltage, so why
only multiple of 1.1 there also.......? plz tell me.

Answer Posted / lokeshraj

Its fine that it is due to form factor.. but my question
was while transforming the supply in step up or strp down
why dont we choose anther voltage not the multiple of 1.1
there... we can choose aby ratio for that.... plz tell me...

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Dear sirs, pls check this 4-20ma to RS485 module datasheet,pls guve me some suggestions. http://www.szsunyuan.com/sy/pro_more.asp?Productid=539 Thanks. E-mail:yunianjiang99@gmail.com

1648


-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.

1548


How to calculate the value of earth capacitance in a transmission line.

1754


After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.

1883


hello!my name is sheikh iam preparing for indian engineering servieces,please send me the old question papers..to sheikhshaazforjobs@gmail.com

1612






What is an iron loss or core loss pi?

607


DRAW ACIRCUIT DIAGRAM OF 100 KVA 415V/55-0-55V DELTA TO STAR TRANSFORMER

1578


5- What is the task (function) of the excitation and isolation transformers in power plant? 6- What is the task (function) of LCI (A), LCI (B) and LCI (COS) in power plant? : LCI (A) and LCI(B) are load commutating inverter for generator turbine starting. , LCI (COS) is load commutating inverter change over switch

3343


How o select the electrical fuse?.What are its characteristics.How to select the material od fuse?

1453


sir pls send the je exam - 2008 and other model question papers..

1638


What is given by the definition in BIL IMP/PF = 950/395 kV. This was found in a name plate of a power transformer.

1814


What is Anemometer used to measure?

656


some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?

1288


what is the path of thunderlightening? once both a buffalo and a person were standing 5m apart but lightening hit and killed buffalo not person?

2413


How is the connection of the tap changer on the HV side been made?

1486