what do u mean by 2/3 soleniod valves?

Answer Posted / r@kesh

There is no 2/3 solenoid valve.
Solenoid valve are of following types:
1. 2/2 solenoid valve
2. 3/2 solenoid valve
3. 4/2 solenoid valve
4. 5/2 solenoid valve

Here top integer indicates ways or ports and bottom integer
indicates positions.

Is This Answer Correct ?    17 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is there any digitel grevity meter availaible in the market by which we can measure specific gravity of a battery?

1893


Tell me the field calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter.

2811


What is the difference bitween control net scaner and device net scaner

3073


how to calculate signal cable sizing? and multipair cable sizing??explain in brief?

1993


How to calibrate Field bus transmitter? procedure ?

1917






give me the formula for analog to digital converter and also d to a converter

2473


why fuse block is not used for AI signal?

1473


If fire would be inside the plant which fire detector is to detected the fire.

1168


Gas equation

1508


How many types of sensor

1250


Why humidity limit is 30 to 55 % for raw material storage?

3770


Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system

1190


How digital input and digital output 's are working in dcs

2132


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

1797


how do we commission inergen system?

1526