Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

DG B-check,C-Check,D-check is depending upon the running
hrs.If the running hrs is not reached as mentioned.How to
conduct the DG checks.

Answer Posted / sk ajibar rahman

"A" - Daily Checks
"B" - 300 Hrs or 6 Months
"C" - 600 Hrs or 12 Months
"D" - 1200 Hrs or 24 Months

Is This Answer Correct ?    27 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is speed mode?

1653


What do you mean by lighting transformer?

994


What was your role in the silicon evaluation/product ramp? What tools did you use?

1914


how to calculate the step resistance for slipring induction motor,how you deside the no of step for that?

2152


What is the permissable nutral current of three phase system as per IS standards?

2046


IN induction motor pf is increased using capacitors.what will be the effect on motor and system when very large capacitor is accidently installed and pf goes leading.

2088


The loads are connected with phase and ground then why current flow as the loads ?

1912


Draw the single line diagram of the power station?

1024


We are planning to synchronized DG's with our captive plant in the event of black start of plant, but before sync we checked voltage of DG with our plant voltage and it varies from 5 V to 450 V. So in this condition how we can sync DG with plant ?

1597


Why back emf used for a dc motor? Highlight its significance.

1125


why the electrolyte level in lead acid battery is maintained 2.5 cms above electrodes?

1814


I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)

1840


what are the range of memory address in plc for L&T lx7 4A

2270


what is the correct format to create a resume for interview??

1915


how to find Harmonics and types as per the equipemnts

1218