How to Calibrate Transducers? Can you give me a step by ste
procedure?
Answer Posted / mahesh bajaj
The transducers are calibrated against reference standards
which are atleast 10 times more accurate then the transducer
to be calibrated.
Let me elaborate by giving an example.
Orifice plate infers flow rate by measuring differential
pressure.so to calibrate orifice plate, reference standard
say magnetic flowmeter is used which measures flow rate.say
flow range is 0-100 lpm and at every 10 lpm, differential
pressure across orifice is measured and constant is evolved
between flow rate and differential pressure. This constant
is also known as discharge coefficient or calibration
constant and one dimensional bernolli's equation is used to
compute this constant.
Now once you know the constant the orifice flow element is
ready to be used in any line size without using any
reference standard.
Hope this helps.
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
what effects a surging can produce in the compressor
Q- What are the application in which PNP transistor is preferred over NPN ?
Draw block digram for well head from well to shipping pump?
Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection
ORP sensor working principle?
what deference between panel earth and systemearth
What are advantages and disadvantage of the ac supply load cell?
Any body have know try work calculation ???
Identification of ss fittings, pilot valves, relief valve.
please someone tell me what is function of vibration sencer and how many types and how to control viberation.please. my id is jimmykhan077@gmail.com
What are the maximum packet size of: a) HART b) Profibus DP c)Profibus PA d) DeviceNet e) Foundation Fieldbus
How to check vortex flow meter is in good condition while we do not having calibration setup?
In Safe Guarding test what means by "Failed to Danger" ?
In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?
Where are oxygen analysers installed in cfbc boilers? What are their usual readings?