What happens if a three phase induction motor is suddenly
single-phased while running? Which type of winding
connection will be affected?

Answer Posted / rajesh sharma

1.if motor conected in STAR than motor two winding burn
2. if motor in DELTA motor one winding burn
3. time duration is depend on load for burning
4. in star R phase is blown than y/b winding burn because
that winding get 440volt and take to much current
5. delta if r phase blown than y pahse winding burn because
only that winding get 440 supply other no.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

(1)WHAT HAPPENS WHEN SUDDENLY LOAD GIVEN TO THE INDUCTION MOTOR ? (2)CAN WE MAKE WOOD AS MAGNET ? (3)WHAT IS THE VALUE OF MAGNETIC FLUX DENSITY IN TRANSFORMER ? (4)WHY WE ARE USING ELECTROMAGNETI NOT ELECTROSTATIC IN MACHINE ?

1683


i am gng to visa interview this july i have 4 backlogs gre 1010,toefl 75,pls give me the tips pls pls

1678


In which of the following case, the rotating magnetic field is reversed? A regenerative breaking B plugging C dynamic breaking D forward motoring

1519


How to setting the volume of RTCC panel AVR (11kv) controller

1189


if the number of poles generated in stator and rotor side of an induction motor are different then what will happen and why?

1366






hi can any body send me syllabus of rrb electrical section engg... and past pepar also of any board...

2144


Give me the calculation steps to design an electromagnet to be work in 230V 50 Hz AC Supply. Also give force that is created by that electromagnet when it gets energized.

1822


in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformer 

1304


why in an industry; machine having rated 200 h.p stopped after power factor is maintained above 0.97 lag by control panel in view-of energy saving

1597


What is knee point voltage of transformer?

687


where we use the SFU & FSU?

1994


what are the safety measures of induction motor?

1595


what are the possible reaons & remedies if resistance of NGR getting heat up

1398


I need a formula to calculate the size of cable as per load but in the terms of length. Please Reply me as i search lot of sites but i did not get the answer.

1610


what is the purpose of bypass mode in energy lighting transformer?

2066