Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we are putting off the APFC(automatic power factor
control) panel while the generator is running?

Answer Posted / k.prakashchandra

APFC is for use while gen is running only.It is not
preferred as it may lead to voltage rise whenever there is
sudden network failure.

Is This Answer Correct ?    1 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is doid

2811


in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly

2299


Whether it is possible to measure energy at the input of rectifier transformer (12 pulse with very high odd harmonics)

1899


what is allowable ac mixing in dc

2096


How to calculate the Harmonics losses in terms of cost/unit.

2022


How can we find the breaking capacity of a Load breaker switch (LBS) fed from 11 kv supply??ex:50KA, 26kA etc???detailed step vice answer pls.

2014


what is quality factor in series resonance circuit and calculate the factor of voltage magnification? how it happens?

1958


What consists of 2 or more thermocouples to be connented series?

2310


How can eliminate noise problem inside temperature controller temp. variation due to contactor chattering problem.

1621


how can maintaince the acb contactor moveing and fixing kit

2067


Determine a suitable number of slors and conductors per slot for the starter 1 winding of a 3 phase, 3300 V. SO Hz 300 rpm alternator. The diameter is 2.3 m

2828


State the points to be considered for selecting a particular type wiring.

2060


how to find number of run cable laying[LT side] for transformer & alternator secondary side? [above condition for getting output power transformer to main panel side] give the example.

2070


why i can not use thimble on capacitor duty contactor

1344


could you measure current in parallel?

1101