Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the permissible value of earth resistance!

Answer Posted / p.gupta.1852

Earth resistance should be as small as possible . It
depands on voltage level of the system to be grounded . As
voltage level increases the earth resistance required to be
nearer to zeero as far as possible . Earth resistance
should not exceed 5 ohm for 433V distribution system and
should be below 1 ohm for 66 KV Grid .

Is This Answer Correct ?    26 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will be the diameter of pipe between conservation tank and transformer

1973


what is basic difference betmeen normal & flame proof motor??

2250


sir please send me techinical questions for junior engineer posting in bangalore railway i am diploma holder

2138


How to work definite,over pluxing,revers power,OSR relay

1858


define superposition theorem thevnin theorem ,norton theorom?

2451


what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?

2957


How to calculate the heat load for a electrical room

3138


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2173


does any one know where we can purchase insulation oil for high voltage oil filled cables

2398


how to calculate the settings for shaft ct protn in hydro generators

2009


by using pump duty, how we will can calculate the motor duty(KW)? is there any standard or formula.

2026


which type of effect of turbine and generator reverse power protection ?

4230


what is meant by brushed alternator & its working principle ?

1974


What are the conditions for sustained oscillator or what is backhouse criterion?

1194


In a carnot engine with an efficiency of 40%, the heat rejected to the sink at 27 C is 60 kJ, then the heat supplied in kJ to the engine by the sources is

1119