Why transformer rating in KVA?
and Generator also?
Answer Posted / deepak
this is because the KVA rating give active plus reactive
power components and the reactive power is associated with
losses of the machines. KW rating tells about the power
being transfered not the losses associated with the process.
Is This Answer Correct ? | 3 Yes | 8 No |
Post New Answer View All Answers
What is Long rod insulator and it's applications..? merits over the disc insulator ..?
Why 11kv to be generated in generation station
how a resistor resists to flow the current?how an inductor oppses the sudden change in current?how a capacitor opposes a DC voltage.
i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.
What is the effect on 3phase induction motor if current setting knob of DOL kept at minimum current?
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
For RCD (Residual current device) Icu is defined. How i can find Ics for them?
How can I calculate ISF of current transformer?
Hi guys! Plz help me to answer the following questions. 1. What are the types of transmission line energy losses? 2. Why are the VLF are used some types of services? 3. What frequencies are used for reliable beyond the horizon terrestrial communication without repeaters? 4. To permit selection of 1 out 16 equi-probable, what is the number of bitis required? 5. What is the most common modulation used for telegraphy? 6. What is the multiplexing is used to increase the capacity of the optic fiber? Thanks
why Y CONNECTION IS BETTER INTERMS OF EFFICIENCY AND P.F FOR A LAOD LESS THAN 40% AND WHY AFTER DELTA IS BETTER FOR > 40%
how is positive, negative, zero sequence is happen.. how is effect on 3 phase system
What is inrush current? how can calculateit? what is the affect of it?
show the single line diagram of star delta starter with single phase preventer
why we used ZNO in Lightning arrester.
what is the common earth