why transformer rating is expressed in kva.
Answer Posted / lokeshraj
For t/f rating kva is used because at the time of
manufacturing of t/f we dont know about the value of the
cos(angle).As Power(KW)=kva*cos(angle).....
....Lokesh
Is This Answer Correct ? | 6 Yes | 12 No |
Post New Answer View All Answers
mostly the questions were from machines... d.c. machines, transformer, synchronous and induction all theory paper........ few from power system... but the level of paper was easy.....
What happens if the negative to earth voltage is greater than positive to earth voltage in the battery of substation?
What is “pu” in electrical engineering?
if the motor rated speed is 950rpm. how to change the above rated speed? is it possible?
Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV
Why line VTG = √3 phase VTG in star? How?
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
How time response of the system is divided?
Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.
We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.
If you have an earth with pilecap then your resistance is really low. why and how?
in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformer
plz tell me,ht and lt panel terminals in substations explain beiefly
Dear all, i completed M.E(Power Electronics & Drives) 2011 passed out having 78% so i need job in core side but i don't know how can i receive the calls from electrical companies and i uploaded my CV in naukri, times jobs etc.. In that iam not recieved any mails from good companies so give me best procedure plzzzzzzzzzzzzzzzzzzzzzzzz..... Thanks, K.Linga Reddy Email-id:-lingareddykmthm@gmail.com Ph no:-08015402078
What is the difference between amorphous core transformer and CRGO core transformer?.