how we are measuring the winding temperature of the
transformer?
Answer Posted / arjunkumar
Mr Vishal u r write but i have confusion on equation
WTI= (Ambient Air Temperature) + (Top Oil Temp. Rise.) +
1.1 X GRADIENT
here what is GRADIENT?CAN WE COUNT GRADIENT VALUE?
IF U HAVE ANY IDEA THEN HELP ME TO ACHIEVE ANSWER.
Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
What is meant by vector group
What are the application of filter?
Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method
What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.
Differentiate between voltage and current feedback in amplifiers?
brief notes on ammeters
what is meaning of bus riser
What is voltage divider rule?
why co incidence factor considered in transformer sizing?
how i can calculate the size for fire cable
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
List examples of current sources?
why genarator genarating voltage 11 KV?
how many types of motor can be used in washing machine
boiler is running in rankine cycle and deisel generator is....?