Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the programming languages used in dcs

Answer Posted / kumaran

i think most of the DCS writing C , C++ language

Is This Answer Correct ?    6 Yes 37 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why even multiple power supplu r used in instrumentation system?

4987


Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.

2280


What is standard of DCS panel design?and what is step of DCS panel design?wiring and type of connector(screw or DB connector)

2111


Explain Gas Turbine startup and shutdown sequences

4321


Why plc require in analog input 4-20amp & 0-10 volt?

1140


plz you help about Que paper of mahagenco previous your,any model paper relad to it{maharastra power genration}

2335


Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.

2218


all types instrumentation questions want

2188


centrifugal compressor interlock? Tell me the parameter at which compressor will trip

3185


What is difference between “Fault Tolerant” & “Fault avoidance” PLC? Application where these system s are used?

3936


Which types of quections asked in interview for FORMULATION PLANT (PHARMA)

6709


Calibration procedure for Electro magnetic Flow meter

4486


Q-Explain the different load conditions that will produced different offset which may or may not be acceptable to thhe control function

2188


hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q

1876


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1945