1. alternator has full load regulation of 4% when pf of the
load is 0.8 lag, 1500 rpm. full load regulation of 1400 rpm
for 0.8lag will be ________ ??
2. torque angle of a sync m/c operating from a constt
voltage bus is usually defined as space angle between _______ .
3. method most effective in finding out no load losses in
large DC shunt motoris ______ .
4. current carrying capacity of fuse material depends on
______ .
5. coil has res. 10 ohm, inductance 1H. what wil be current
after 0.1sec after switching on to a 500V DC SUPPL ? ?
6. effect of phase lag compensation on servo systems
___________ .
7. rotor of a dc machine is usually supported upon ______ .
8. DC motor is preferred to AC motor in which application ??
9. 3 nos of 10:1 Xmer are connected in Star-Delta to supply
a load at 230V.the supply voltage must be ______ .
10. voltage source produces max current in which circuit.
11. cal. power, if current and voltage are out of phase by
90 degree.
12. suitable length of Xmission line of power at 66 KV.
13. Which of the theorm helps in simple computation when the
load across a ckt is varying ??
14. what is the adopted line length for power Xmission of
power by cables ??
Answer Posted / rupesh thakkar
ans no -12
false
true answer is 220kv or 44okv
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
Testing procedure of DG alternator stability test
I Have 3 Phase 10 KW AC Alternator i found one phase weak, so what will be the reason & what action shouls i take to rectify the same.
Why we do 2 types of earthing on transformer (ie:)body earthing & neutral earthing , what is function. I am going to install a oo kva transformer & 380 kva dg set what should the earthing value?
What is the difference between isolators and electrical circuit breakers?
What is effect of over voltage and under voltage on ACB
tell me about roaster switch .& what is the function in transmission & distribution?
why any centrifugal blower draw more current in starting. consider id fan and fd fan?
errection check list for transformer maintenance
can we use engine degreaser for electrical motors?
what is saturation kit?which use above 15 kw motors panel side.
explain the function of brush less dc motor?
What does ampere turns shows?
We have 5 Distribution sections with variable loads&We have 3 Gensets(500kva,380kva&250kva) our total load is between 400kva to 600kva. so how could we connect 3gensets.
What are capacitive,resistive,inductive surge absorbation? What is ferranti surge absorber? What is lagrangian cost? What is Px operator?
Instrument connected to a single phase supply