1. alternator has full load regulation of 4% when pf of the
load is 0.8 lag, 1500 rpm. full load regulation of 1400 rpm
for 0.8lag will be ________ ??
2. torque angle of a sync m/c operating from a constt
voltage bus is usually defined as space angle between _______ .
3. method most effective in finding out no load losses in
large DC shunt motoris ______ .
4. current carrying capacity of fuse material depends on
______ .
5. coil has res. 10 ohm, inductance 1H. what wil be current
after 0.1sec after switching on to a 500V DC SUPPL ? ?
6. effect of phase lag compensation on servo systems
___________ .
7. rotor of a dc machine is usually supported upon ______ .
8. DC motor is preferred to AC motor in which application ??
9. 3 nos of 10:1 Xmer are connected in Star-Delta to supply
a load at 230V.the supply voltage must be ______ .
10. voltage source produces max current in which circuit.
11. cal. power, if current and voltage are out of phase by
90 degree.
12. suitable length of Xmission line of power at 66 KV.
13. Which of the theorm helps in simple computation when the
load across a ckt is varying ??
14. what is the adopted line length for power Xmission of
power by cables ??
Answer Posted / rupesh thakkar
ans no -12
false
true answer is 220kv or 44okv
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
i am gng to visa interview this july i have 4 backlogs gre 1010,toefl 75,pls give me the tips pls pls
Iwould like to know barc interview questions
how line turns ratio changes in 3 phase with change in connection
what is solkor relay and which condition it will act?
how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .
How you will determine the volume of oil in a particular Distribution transformer.
What is Load sharing of Transformer ?
one conductor length is L.and i am strech uniformly this conductor and made length is 2L.so resistance of this strech conductor is R=4R..but i want to know about area of stech conductor hows it become a/2..
How Can You Relate Power Engineering With Electrical Engineering?
How many types of faults are there in 3 phase power system?
why single phase to grd test in HV cable?why not 2 phase at a time?
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
what is the working process of over & under voltage relay.
what is difference between elr and R eartl realy.