Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the diff. between power transformer & distribution
transformer.....

Answer Posted / rsundareee

The major difference B/W Ptr and DTr ,
* The power trans is step down and step up the High voltage
(HV-3Phase to 3Phase system)-for substation purpose
* The power trans have rating up to 500mVA(up to 400kV)
* The Distribution trans is step down voltage(HV to LV
Side -3Phase to 3Phase 4 wire system)-for domestic consumer
* The power trans have rating up to 50mVA(33,22,11kV to
0.415kV

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can calculation ate Amps for cabel. Ex-for 1sqmm wire hou many amps we can draw

2448


in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply

2104


what is ratio of copper wire size and current ?

1822


Why we are going for converter transformers for DC drives application instead of distribution transformer?

1996


what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?

2389


where was current transformer protection units used and why??

2032


What is dc current source?

1289


by what factor the starting current is used when comparing star and delta connection for motor starting?

2064


I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

4026


we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain

2212


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2752


What is a commutator?

1040


what happen when we add mentos in cold drink?& why?

2046


how we sesign the transformer give some specifion regarding design of transformers

1911


any body,pls tell me how to done relay coordination ? how to coordinate by TCC curve?how to read the tcc curve?

2137