Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In the test for control of absorbance in UV calibration why
do we use only potassium dichromate and what is purpose of
taking a specified amount of 57.0-63.0mg?

Answer Posted / devidas

it show the maxima at 235nm,257nm,313nm, and 350nm in UV
region. and it consider as a primary standard which is high
purity

Is This Answer Correct ?    18 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is importance of pH in the Heavy metal test and How it effect on the test results?

2277


if you have given a blank water how you analyse by general analytical techniques?

2024


in hplc chromatogram started from left to right and in uv spectrum started from left to right

941


how you establish the LOQ?

780


How to fix the sample conc. in Related substances test by HPLC?

1085


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

817


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2306


Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc

1457


Why perchloric acid used for potentiometric titration

2669


how you confirm the assay method?

761


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3659


why we use a particular hplc column for a particular compound give reasons?please

2746


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4055


How require to perform linearity as per ANVISA? What are the acceptance criteria?

1325


what is the principle of UV Vis spectroscopy, AAS, ICP OES,ICPAES, ICP-MS and FTIR

9241