Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

where HT & LT capacitor uses ?

Answer Posted / rajendra

These capacitors are designed for protection of large
rotating machines such as motors & generators. At the time
of over voltage during electric storms produces surges to
electrical equipments connected to system. The voltage
stress between turns of multi turn coil sets a limitation
and surge voltage causes breakdown of turn to turn
insulation resulting in short circuited turns.

Is This Answer Correct ?    5 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?

2149


Is it possible to protect 3phase overload and earth fault of the 3phase system using two CT's.

2123


Which level of the Transformer oil got dielectric strengh? And why?

2259


Why air circuit breaker off due to power failure?

1219


Explain in brief description about the operation of DG sets.

2452


rajha power sector details

2029


Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC

1604


In CTs tan delta point should be earthed , what is the reason behind it?

3029


How to know the following data of synchronous generator 1. D-Axis Unsaturated Reactance 2. D-Axis Unsaturated Transient Reactance 3. D-Axis Unsaturated Sub - Transient Reactance

2021


a 230v transformer with step down ratio 19:1.it has 2000turns on primary and rated 25va calculate max primary current no of secondary turns volts/turn

1547


What is the one main difference between ups & inverter ? And electrical engineering & electronics engineering ?

1145


What is open delta Xformer? It's adavntages & Use?

2239


why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?

1798


How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.

5393


in Telecom DC system-why positive +ve is made earthed.and - ve is fed to load.

2703