1.In two wattmeter method if one wattmeter shows Negative
reading then wat is reason?
2.Wat is the reason for low voltage in houses?
3.Wat is meant by current and voltage? wat is difference
between the two?
Answer Posted / dileep
two watt meter method is used in measurement of power under un balanced condition.there are two reasons for - ve value
1). if load consist of more inductivd or capacive load with negligible resistive then it will show _ve value .pf angle is more than 65 deg
. in case of induction motor no load test one of the watt meter will indicate _ve because no load pf is 0.2 lag pf angle is nearer to 75 deg
2).reverse. connections of current coil
| Is This Answer Correct ? | 98 Yes | 6 No |
Post New Answer View All Answers
sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah
Power Factor Correction Panel (Manual & Automatic)
What is creepage distance..... what will be the value for different voltage level
How does an induction motor start?
What is the formula to find out two phase active & reactive power
List examples of voltage source?
what is the sludge current
why transmission is only 3 phase and not 2 or 4 or poly phases
what is the ms flat constant for calculating earth mat design calculation?
Explain cmrr?
how a flip flop can be used as a latch?
How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.
What is essential to prove safe isolation of electrical circuit?
What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?
what are the possible reaons & remedies if resistance of NGR getting heat up