Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between megger & Contact resistance
meter & its Application?

Answer Posted / p. sudhagar

Megger is used to checking in insulation value,Its used to
high voltage injunction purpose and checking the polarity.
Contact resistance meter used to checked the contact
resistance value, Its injected the 100A only So its
resistance value low.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the steps involved in generator load test?

1553


what is the use of expulsition protective gap in 11Kv line.

2130


Show the schematic arrangement of diesel power station layout and give its principle of operation.

3038


STATE USE OF ARC RUNNERS & SPLITTERS ?

1948


What mean by MLTP

3950


in star-delta tranformer,if the input of star connection is 400/7v 3 kva then what is the output of delta connection?

2134


how slip power recovery system work

3025


What is servo lock in CNC how they work and if any parameter for them in CNC machine

5349


Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar

1825


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2475


differnce between single acting and double acting solenoid valves

1844


What are the disadvantages of autotransformer?

1116


Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT? 

1962


why impudance relay used for medium transmission power system? why not others?

1471


How shall i select the value of capacitor or inductor in a system?

1900