why our indian system choose the 230 volt for single
phase&415 for 3-phase voltage,in forign side 110 volt is
used what is the difference
Answer Posted / muhammad ashraf
In forign countries, they use 200V in three phae at 60 HZ
and according to the principal of electrical theory in star
connection phase voltages are under root 3 time less then
line voltages, and for domestic control we use star
connection, this the reason that in India and Pakistan we
use 415V three phase supply and according to the formula
single phase voltages will be 230, and according to this
standard our home appliances are design at 230 volts. And
forigner use 200V three phase supply And according to the
formula thier single phase voltages are 110V. And thier
design of home applinces are 110V.
| Is This Answer Correct ? | 7 Yes | 2 No |
Post New Answer View All Answers
An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?
How does the slip regulator works as a startor
SIR, GIVE ME OPGW SAG CALCULATION FORMULA I AM DAE ELECTRICAL. THANKS
Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.
Witch do depand of Power factor and theory of power factor?
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
1. What is maximum permissible distance between smoke detectors ? 2. How do we decide number of smoke detectors required in a large office, warehouse, hall etc ? 3. What should be maximum height of smoke detectors ? 4. Where do we use heat detector, optical smoke detector, temperature sensitive detector ?
A system absorbs 100 k J of heat and the increase in its internal energy is 100 kJ; the work done is
How many sprinklers should be in one pipe line?
Why we use Electrical energy rather than any other type of energy, mostly? Explain behavior of open secondary CT and short circuited secondary PT in energized condition?
what is the k var ratting of 1250kva
FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?
ELECTRICAL DRIVES: can a motor load system with passive load torque can have equilibrium speed in second quadrant
Why 11kv to be generated in generation station