Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the voltage between the earth & neutral
2 is there any continuity TO BE between earth & NEUTRAL

Answer Posted / jais thomas

THE EFFECTIVE VOLTAGE BETWEEN THE N AND E OF A SYSTEM
SHOULD BE ZERO WHICH MEANS THERE IS NO SHORTING,
DEFINITELY THERE WILL BE CONTINUITY BETWEEN N AND E BECAUSE
THE N THAT IS GENERATED IN A STAR SYSTEM TRANSFORMER IS
GROUNDED WHICH MEANS THAT THERE IS A CONTINUITY IN N AND
E.THIS SHORTING BETWEEN N AND E SHOULD ONLY BE IN THE
TRANSFORMER LEVEL AND NOT IN ANY OTHER PART OF THE SYSTEM

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2185


how to select the double earth conductor if 21A full load?

2068


why and where we use early make & late break contacts in protection?

8324


Explain about how is it working Earth fault'relay and wahts the resistance value of earth bed

1535


at meter room 50 hrc switch installed,but there are not get earthing proper,so what happen?and 11kv transformer out put going in to hrc main 400a three nog each? so earthing is require for all switch? (some customer made earthing at there home.)

1911


What happen in ups if phase reverse?

2291


What is Anemometer used to measure?

1126


What is the meaning of 40X8X2 busbar dimensions for carring load of 400 Amps

1999


with help of neat sketch explain principle of TIG welding process

1966


what kinds of Transformer oil grade is better for power transformer ?

1644


Control cables in S's will carry 1000v which is AC R DC? Pls answer meĀ 

2156


Why power genaration in India is at 50HZ while America its 60HZ

2289


Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?

2126


How to calculate multiplying factor of dc energy meter

1668


Do inductive loads have distorted current waveforms ?

1948