I need to compare the energy consumption of an industrial
machine before and after improving. Shall I compare the
apparent power or the active power? I know usually
factories use compensated capacitors (or other similar
components) to compensate the reactive power, so if I use
the apparent power, it's not the real power consumed.
Answer Posted / prakash
just go for the electricity board meter, that all
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What should be the height of basement according to NBCC code?
Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?
WHAT R THE SAFETIES IN A HIGH TENSION PANEL N LOW TENSION PANEL. ALSO WAT SAFETIES R THERE IN A 200 KVA TRANSFORMER?
why swinburnes test cannot be performed on series machines?explain
why occ characteristics of generator is also called as magnatization characteristics ?
Determine a suitable number of slors and conductors per slot for the starter 1 winding of a 3 phase, 3300 V. SO Hz 300 rpm alternator. The diameter is 2.3 m
What is the suitable transmission voltage?
As we use capacitior bank in 3ph ckt for improvement of PF, why not we use capacitor in single phase domestric use, at our house their are many inductive equipments,like fan,mixer,tube choke,air conditioner they also draw PF... by using capacitor can they improve PF. if yes--what are advantage and how to connect a capactor in single ph,and which type of capacitor if no- what are disadvantages.
at which voltage level arcing ground is occurs ??????????
what is the use of vcb & isolator in substation?
Draw a circuit diagram in which if button is open we can use socket and bulb as a series test circit and if button is close than simple we can use socket as any load purpose.
can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?
If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?
Meter p.t. ratio= 3×230/400 , c.t.ratio = 3×1 (2) A what is m.f.
What is the difference between AC and DC injection methods for rotor earth fault protection