what is the difference between(Flame proof/Explosion proof)&
Fire proof instruments.Both are same or different & if
different in which way because the transmitter which have
approved ATEX flame proof enclouser but it use PTPE O ring
& PTFE Head Gasket,so its (fire safe/fire proof)????????
Answer Posted / a.pitchiah
All the answers avoid the direct question. In my opinion
Falme Proof and Explosion Proof mean one and the same,
going through various indirect references.
Fire Proof is different, since the constuction of the items
must be of fireproof materials.Explosionproof or flameproof
need not necessarily be fireproof.
Please comment.
| Is This Answer Correct ? | 15 Yes | 2 No |
Post New Answer View All Answers
in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.
how to calibrate corollaries (Mass flow meter)?
all types of liquid analyzer principle with drawing?
I have 0.75mm sq multicore cable (IS type) , can use instead of same type but 1.5 sq mm cable ? Note : The distance is around about 150 meter.
find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s
Why boiler chimney area oxyden sensor fixing?
IS there any effect of vortex in low pressure side of the transmiter after the orific in feed water line? if yes then what is the calculation?
How can you add value to this Industry if offered the job?
dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,
What is the advantage of using locally fabricated hook ups over Pre fabricated hook ups in process instrumentation?
how to convert cubic metre per hour to newton cubic metre per hour
please can any one tell me clearly about pid tuning i am confusing about this .how to tune pid easly?
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
Describe the function of Accumulator into the Pump