Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How are PDA Detector work in HPLC

Answer Posted / binay mishra

PHOTO DIODE ARRAY DETECTOR WORKS JUST AS SIMPLE UV
DETECTOR,BUT ONL Y THE BASIC DIFFERENCE IS THAT PDA IS USED
TO OBTAIN THE SPECTRUM ,MEANS IT IS USED TO SCAN THE SAMPLE
THROUGH OUT THE SELECTED WAVELENGTH RANGE WHILE IN UV
DETECTER WE CAH TAKE THE ABSORBANCE OF SAMPLE AT FIXED
WAVELENGTH.

IN CASE OF PDA FUNCTION, FILTER OF SPECTROSCOPE ALLOWS TO
PASS ALL THE SELECTED WAVELENGTH'S RAY OF LIGHT REFLECTED
FROM GRATING AND THUS WE GET SPECTRA.

SO , PDA CAN BE USED FOR SPECIFICITY STUDY.

Is This Answer Correct ?    10 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

mode of absorption in alimentary canal?

2392


AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2057


mahagenco syllabus for the post of chemist

6477


Why we use potassium dichromate in uv calibration Exact reason behind it??

1259


for inorganic molecules require to do RS, Assay and disso?

734


analytical method validation require to with respect to release specification or shelf life specification?

794


WHAT IS THE PURPOSE WE USE HCL, CHOPPER, BURNER, MONOCHROMATOR in AAS? PLEASE EXPLAIN BRIEFLY

2609


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1854


How require to perform linearity as per ANVISA? What are the acceptance criteria?

1337


why salisylic acid not using now days for disdolution calibration?

773


How we choose the mobile phase for method development.?

1214


How to start the dissolution development for unknown tab?

1680


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2578


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1872


what is procedure of actual procedure for registration of drug?

2012