Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in 3 phase (4 wire) star connection - is current pass through
neutral??

Answer Posted / md. obaydur rahman

We know that,in a star connection for balanced condition the
phasor sum of three line current is zero. As a result in
balanced condition there is no neutral current. But in
unbalanced condition the sum is not zero and a current is
flowed through the neutral wire.

Is This Answer Correct ?    7 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between b c d curves on mcb

1755


A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1817


Can I use star delta connected induction motor for dual supply voltage?

1898


Why electrical power generation and transmission done in 3 phase system not more than 3 phase ?

3001


what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?

1563


what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?

1460


redundant connection in contactor?

2439


our factory is going under construction mean time transformer 1000 kva 2 nos &load break swithch 12 kv & 4 nos 750 kva 2 nos & 380 kva 2 nos generator to be errcted.how to arrange earth pits &how to earth connect & neutral pit how to calculate in earth bit size.

2059


how solar power plant energy meter multiplication factor

2032


What is the purpose of stablization resistor in high impedance bus bar protection

1947


What are the basic component of a cro?

1182


Can you please explain creepage distance in detail, for a 6.6kV cable head what must the distance be and how do you determine it?

2814


what will happen if frequency is below 50 hz?

1958


What is the estimated total hydropower potential of india?

1085


An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.

1354