i want to know is it possible to generate usefull power by
coupling generator with motor & supply gives to motor by
battery source then generator generates power. remove the
battery source given to the motor & feed the supply from
some of the generated power supply to the motor & motor
runs continously. generator generate power contnously.is it
possible ?
Answer Posted / suresh5254
It is not possible.........to do so either motor or
alternator efficiency should be more than 100% which is not
possible.....
Ex.. let motor i/p power= P1
o/p power= p2
generator i/p power= q1
o/p power= q2
here p2 cannot be more than p1 ,lly q2 cannot be more than
q1 because of copper,friction and windage losses......so
obviously q2 lesser than p1....so motor cannot run
Note: Energy neither be created nor destroyed...only it can
be transferred from one form 2 other....
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
How many types of losses occur in a transformer?
In a Impedance Based Distance Relay (Quad Characteristics) - Could there be two different Line Angle(RCA) for Ph-Ph & Ph-Gnd? If So Kindly Let me Know.. Where, What are the advantages of the same?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
How may I enrol or get admission to your program?
3 phase induction motor connection star or delta while using ac drive motor is .75 to 5.5 kw
whatis the commertial spec. of distribution boards ?
In a voltage-controlled current source A A current booster is never used B The load is always floated C A stiff current source drives the load D The load current equals Isc
What happens to voltage when current is zero?
how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???
what is a pulse transformer? how rise time of pulse changes when ever the voltage changes?
What is the difference between alternator and generator?
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance
What is the disadventage of gland earthing(power cable) if any. ?
why US countries maintains 110v and 60HZ
Incoming line 11kv And transformer capacity is 2500kva. Consumption load is 1300A. Then fuse capacity is 11kv line.