what is the difference between the electrical and
electronic choke?
Answer Posted / sroy
electrical and eletronic choke both regulate the current
flow to the lamp....whereas starter is not required in case
of electronic one. it saves energy as the ac period of
current is shorter than relaxation time required to
deionize the mercury atoms. in electrical choke ions will
have to be reionized ,,but in electronic they dont allow it
to settle down and hence requires less energy
| Is This Answer Correct ? | 17 Yes | 6 No |
Post New Answer View All Answers
Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.
in our all power plant have connected in grid and grid voltage and plant voltage is same, but as per as electrical concept the power will transmit from high potential to low potential but here altough same,then how power transmit from power plant to grid.
explain why core loss of a transformer is almost constant under different load conditions when connected across a constant voltage and constant frequency.
why all the feeders are designed in a particular manner ... is there any reason for that???
please send me jindal previous aptitude and technical question and answer.my email id is deep_raj@live.com
what is the use of expulsition protective gap in 11Kv line.
What is the difference between hot and cold loop testing?
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?
what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?
What is I to C?
what will happens if one phase is missing for 33/11kv power transfomer and why?
What is A check, B check, C Check & D check for a diesel Generat
What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?
how does a submersible pump work..?